LUN23- Three Phase Active-Reactive Meter
TECHNICAL SPECIFICATIONS
3 phase 4 wire three phase meter
Active-Reactive / Import-Export
Acitve: B/C – Reactive: 2 class
Direct connected
5(100)A current

3×230/400VAC reference voltage

1000 imp/kWh – 1000 imp/kVArh
-40°C…+70°C temperature range
IP54 protection class
188 segments LCD screen
Optical port communication
OPTIONAL FEATURES
RS485 comm. port
PLC comm. module
GSM comm. module
RF comm. module
RF-ID module option
Magnetic intervention
detect and record
LCD backlight
Export energy measurement
Total Harmonic Distortion
(THD) measurement
LSM35- Three Phase Active-Reactive Meter
TECHNICAL SPECIFICATIONS
3 phase 4 wire three phase meter
Active-Reactive / Import-Export
Acitve: B/C – Reactive: 2 class
Direct connected
5(100)A current

3×230/400VAC reference voltage

1000 imp/kWh – 1000 imp/kVArh
-40°C…+70°C temperature range
IP54 protection class
188 segments LCD screen
Optical port communication
OPTIONAL FEATURES
RS485 comm. port
PLC comm. module
GSM comm. module
RF comm. module
RF-ID module option
Magnetic intervention
detect and record
LCD backlight
Export energy measurement
Total Harmonic Distortion
(THD) measurement
LSM40- Three Phase Active-Reactive Meter
TECHNICAL SPECIFICATIONS
3 phase 4 wire three phase meter
Active-Reactive / Import-Export
Acitve: B/C – Reactive: 2 class
Direct connected
5(100)A current
3×230/400VAC
reference voltage
1000 imp/kWh – 1000 imp/kVArh
-40°C…+70°C temperature range
IP54 protection class
188 segments LCD screen
Optical port communication
OPTIONAL FEATURES
RS485 comm. port
PLC comm. module
GSM comm. module
RF comm. module
RF-ID module option
DLMS-Cosem support
Magnetic intervention detect and record
LCD backlight
Export energy measurement
Total Harmonic Distortion (THD) measurement
LSM45- Three Phase Active-Reactive Meter
TECHNICAL SPECIFICATIONS
3 phase 4 wire three phase meter
Active-Reactive / Import-Export
Acitve: B/C – Reactive: 2 class
Direct connected
5(100)A current
3×230/400VAC
reference voltage
1000 imp/kWh – 1000 imp/kVArh
-40°C…+70°C temperature range
IP54 protection class
188 segments LCD screen
Optical port communication
OPTIONAL FEATURES
RS485 comm. port
RF-ID module option
Magnetic intervention detect and record
Latching relay (100A)
LCD backlight
Export energy measurement
Total Harmonic Distortion (THD) measurement
PLUG&PLAY MODULES
PLC comm. module
GSM comm. module
RF comm. module
Ethernet module
LSM50- Three Phase Active-Reactive Meter
TECHNICAL SPECIFICATIONS
3 phase 4 wire three phase meter
Active-Reactive / Import-Export
Acitve: B/C – Reactive: 2 class
CT/CT-VT connected
1(6)A current
3×58/100VAC – 3×230/400VAC
reference voltage
10.000 imp/kWh – 10.000 imp/kVArh
-40°C…+70°C temperature range
IP54 protection class
188 segments LCD screen
Optical port communication
OPTIONAL FEATURES
RS485 comm. port
PLC comm. module
GSM comm. module
RF comm. module
RF-ID module option
DLMS-Cosem support
Magnetic intervention detect and record
LCD backlight
Export energy measurement
Total Harmonic Distortion (THD) measurement
LSM55- Three Phase Active-Reactive Meter
TECHNICAL SPECIFICATIONS
3 phase 4 wire three phase meter
Active-Reactive / Import-Export
Acitve: B/C – Reactive: 2 class
CT/CT-VT connected
1(6)A current
3×58/100VAC – 3×230/400VAC
reference voltage
10.000 imp/kWh – 10.000 imp/kVArh
-40°C…+70°C temperature range
IP54 protection class
188 segments LCD screen
Optical port communication
OPTIONAL FEATURES
RS485 comm. port
RF-ID module option
Magnetic intervention detect and record
LCD backlight
Export energy measurement
Total Harmonic Distortion (THD) measurement
PLUG&PLAY MODULES
PLC comm. module
GSM comm. module
RF comm. module
Ethernet module
LUN51- Three Phase Active-Reactive Meter
TECHNICAL SPECIFICATIONS
3 phase 4 wire three phase meter
Active-Reactive / Import-Export
Acitve: B/C – Reactive: 2 class
CT/CT-VT connected
1(6)A current
3×58/100VAC – 3×230/400VAC
reference voltage
10.000 imp/kWh – 10.000 imp/kVArh
-40°C…+70°C temperature range
IP54 protection class
188 segments LCD screen
Optical port communication
OPTIONAL FEATURES
RS485 comm. port
PLC comm. module
GSM comm. module
RF comm. module
RF-ID module option
DLMS-Cosem support
Magnetic intervention detect and record
LCD backlight
Export energy measurement
Total Harmonic Distortion (THD) measurement